An kera wannan samfurin kuma an haɓaka shi cikin yarjejeniya tare da dokoki masu zuwa, umarni da ƙa'idodin ƙira:
Umarnin Majalisar 93/42/EEC na 14 Yuni 1993 game da na'urorin kiwon lafiya(Alamar CE).
TS EN ISO 13485 Na'urar likitanci - Tsarin gudanarwa mai inganci - Abubuwan buƙatu don tsari
dalilai..
TS EN ISO 14971 Na'urorin likitanci - Aikace-aikacen sarrafa haɗari ga na'urorin likitanci
TS EN ISO 15223-1 Na'urorin likitanci - Alamomin da za a yi amfani da su tare da alamun na'urar likitanci, lakabi da bayanin da za a kawo - Kashi 1: Gabaɗaya buƙatun
◆International Electrotechnical Commission (IEC), ana la'akari da waɗannan ka'idoji musamman.
Daidaiton Magana | Lakabi |
TS EN 60601-2-54: 2009 | Kayan aikin lantarki na likitanci - Kashi 2-54: Abubuwan buƙatu na musamman don aminci na asali da mahimman aikin kayan aikin X-ray don rediyo da rediyo |
Saukewa: IEC60526 | Babban filogi na USB da haɗin kai don kayan aikin X-ray na likita |
IEC 60522: 1999 | Ƙaddamar da dindindin tacewa na X-ray tube majalisai |
Saukewa: IEC 60613-2010 | Lantarki, thermal da abubuwan lodi na jujjuyawar bututun X-ray na anode don ganewar asibiti |
IEC60601-1: 2006 | Kayan aikin lantarki na likita - Kashi 1: Gabaɗaya buƙatun don aminci na asali da mahimman aiki |
IEC 60601-1-3: 2008 | Kayan aikin lantarki na likitanci - Kashi 1-3: Gabaɗayan buƙatun don aminci na asali da aiki mai mahimmanci - Matsayin haɗin gwiwa: Kariyar Radiation a cikin kayan bincike na X-ray |
IEC60601-2-28: 2010 | Kayan aikin lantarki na likita - Kashi 2-28: Abubuwan buƙatu na musamman don aminci na asali da aiwatar da mahimman ayyukan tarukan bututun X-ray don ganewar asibiti |
IEC 60336-2005 | Kayan aikin lantarki na likitanci-Tattaunawar bututun X-ray don ganewar asibiti-Halayen wuraren mai da hankali |
●Nadin ya kunshi kamar haka:
MWHX7010 | Tube | A | High ƙarfin lantarki soket tare da 90 digiri shugabanci |
MWTX70-1.0/2.0-125 | B | High ƙarfin lantarki soket tare da 270 digiri shugabanci |
Dukiya | Ƙayyadaddun bayanai | Daidaitawa | |
Ƙarfin shigar da ƙima (s) na anode | F 1 | F 2 | Saukewa: IEC60613 |
21kW (50/60Hz) | 42.5kW (50/60Hz) | ||
Anode zafi ajiya iya aiki | 100 kJ (140kHU) | Saukewa: IEC60613 | |
Matsakaicin ƙarfin sanyaya na anode | 475W | ||
Ƙarfin ajiyar zafi | 900kJ | ||
Max. ci gaba da zubar da zafi ba tare da madauwari ta iska ba | 180W | ||
Abun anodeAnode saman shafi abu | Rhenium-Tungsten-TZM(RTM) Rhenium-Tungsten (RT) | ||
kusurwar manufa (Ref: axis axis) | 16 ° | Saukewa: IEC60788 | |
X-ray tube taro muhimmi tacewa | 1.5 mm Al / 75kV | Saukewa: IEC 60601-1-3 | |
Ƙimar ƙima (s) tabo mai mahimmanci | F1 (karamin mayar da hankali) | F2 (babban mayar da hankali) | Saukewa: IEC60336 |
1.0 | 2.0 | ||
X-ray tube nominal irin ƙarfin lantarkiRadiographic Fluoroscopic | 125kV 100kV | Saukewa: IEC60613 | |
Bayanai akan dumama cathode Max. halin yanzu Max ƙarfin lantarki | ≈ / AC, <20 kHz | ||
F1 | F 2 | ||
5.1 A ≈5.8~7.8V | 5.1 A ≈7.7~10.4 V | ||
Leakage radiation a 150 kV/3mA a 1m nesa | ≤1.0mGy/h | Saukewa: IEC60601-1-3 | |
Matsakaicin filin radiyo | 573×573mm a SID 1m | ||
X-ray tube taro nauyi | Kimanin 18 kg |
Iyaka | Iyakokin Aiki | Iyakokin sufuri da Ma'aji |
Yanayin yanayi | Daga 10℃zuwa 40℃ | Daga - 20℃to 70℃ |
Dangi zafi | ≤75% | ≤93% |
Barometric matsa lamba | Daga 70kPa zuwa 106kPa | Daga 70kPa zuwa 106kPa |
1-phase stator
Wurin gwaji | C-M | C-A |
Juriya mai iska | ≈18.0…22.0Ω | ≈45.0…55.0Ω |
Matsakaicin ƙarfin ƙarfin aiki da aka yarda (gudu) | 230V± 10% | |
Ya ba da shawarar wutar lantarki mai aiki (gudu) | 160V± 10% | |
Wutar birki | Saukewa: 70VDC | |
Gudun wutar lantarki a cikin fallasa | 80Vrms | |
Gudun wutar lantarki a cikin fluoroscopy | 20V-40Vrms | |
Lokacin gudu (ya danganta da tsarin farawa) | 1.2s |
Gargaɗi don yin mu'amala da Generator X-ray
1.Rufewar Gidaje
Kada a taɓa shigar da ƙarfin da aka ƙima zuwa taron bututun X-ray
Idan ƙarfin shigarwar ya wuce ƙayyadaddun bututu, zai iya haifar da anode don yin zafi, gilashin bututun ya farfashe, kuma a ƙarshe na iya haifar da matsaloli masu tsanani saboda yawan ƙarfin da ya haifar da tururin mai a cikin taron gidaje. A cikin yanayi mai mahimmanci inda gidaje ke rushewa saboda nauyin nauyi, mai iya canza yanayin zafi mai aminci ba zai iya kare bututun X-ray ba, koda kuwa yana aiki.
*Rushewar sassan rufe gidaje.
*Raunin dan Adam da ya hada da konewa sakamakon tserewar mai mai zafi.
*Hadarin gobara sakamakon harin anode mai kunna wuta.
Ya kamata janareta na X-ray ya kasance yana da aikin kariya wanda ke sarrafa ikon shigarwa don kasancewa cikin ƙayyadaddun bututu.
2.Cikin Wutar Lantarki
Don guje wa haɗarin girgizar lantarki, wannan kayan aikin dole ne a haɗa shi da wadatar ƙasa mai kariya kawai.
3.Ba a yarda da gyaran wannan kayan aiki ba!!
Tsanaki don yin mu'amala tare da Generator X-ray
1.Over Rating
Yawan kuzari da yawa a cikin harbi ɗaya na iya haifar da gazawar taron bututun X-ray.Yana da mahimmanci a bita a hankali takardar bayanan fasaha kuma bi ƙayyadaddun umarnin don guje wa lalacewa.
2.Tace Dindindin
Dokokin doka sun ƙididdige jimlar adadin tacewa da ake buƙata da mafi ƙarancin nisa tsakanin wurin mai da hankali na X-ray da jikin ɗan adam.
They ya kamata a bi ka'ida.
3.Safety Thermal Sauyawa
Haɗin bututun X-ray yana da canjin yanayin zafi mai aminci don hana ƙarin ƙarfin shigarwa lokacin da gidajen bututun ya kai ga zafin jiki(80℃)na sauya-bude.
Ba a ba da shawarar maɓalli don haɗa na'urar stator a cikin jerin da'ira ba.
Ko da maɓallin yana aiki, kar a taɓa kashe wutar tsarin. Ya kamata a kunna naúrar sanyaya idan an yi amfani da shi tare da tsarin.
4.Aikin da ba a zata ba
Tattaunawar bututun X-ray na iya yin rashin aiki ko kasawa ba zato ba tsammani, yana haifar da haɗarin manyan matsaloli. Yana da mahimmanci a samar da wani tsari na gaggawa don hanawa da warware duk wata matsala da ka iya tasowa daga wannan hadarin.
5.Sabon Application
Idan kuna shirin amfani da wannan samfurin a cikin sabon aikace-aikacen da ba a bayyana ba a cikin wannan takaddar, ko kuma idan kuna shirin amfani da wani nau'in janareta na X-ray, da fatan za a tuntuɓe mu don tabbatar da dacewa da samuwa.
1 .X-ray Radiationkariya
Wannan samfurin ya cika buƙatun IEC 60601-1-3.
Wannan taron bututun X-ray yana fitar da hasken X-ray a cikin aiki.Ma'aikatan da suka cancanta da horarwa kawai ake ba su damar yin aiki da taron tube na X-ray.
Abubuwan da suka dace na ilimin lissafi na iya haifar da lahani ga majiyyaci, ƙirar tsarin yakamata ya ɗauki kariya mai kyau don guje wa radiation ionization.
2.Dielectric 0il
Haɗin bututun X-ray yana da dielectric 0il ƙunshe don kwanciyar hankali mai ƙarfi. Kamar yadda yake da guba ga lafiyar dan adam,idan an fallasa shi zuwa wurin da ba a iyakance shi ba,ya kamata a yi watsi da shi kamar bin ka'idar gida.
3 .Operation Atmosphere
Ba a yarda a yi amfani da taron bututun X-ray a cikin yanayi na iskar gas mai ƙonewa ko mai lalacewa ·
4.Daidaita Tube Current
Dangane da yanayin aiki,za a iya canza halayen filament.
Wannan canjin zai iya kaiwa ga yawan fiddawa ga haɗewar bututun X-ray.
Don hana haɗuwar bututun X-ray daga lalacewa,daidaita bututu a kai a kai.
Bayan lokacin da bututun X-ray yana da Matsala a cikin alamfani da lokaci,Ana buƙatar daidaita yanayin halin yanzu na bututu.
5.X-ray Tube Zazzabi
Kar a taɓa saman bututun X-ray bayan an yi aiki saboda yawan zafin jiki.
Tsaya bututun X-ray don sanyaya.
6.Iyakokin aiki
Kafin amfani,da fatan za a tabbatar da yanayin muhalli yana cikin Iimits na aiki.
7.Duk wani rashin aiki
P1ease tuntuɓar SAILRAY nan take,idan an lura da wani rashin aiki na taron bututun X-ray.
8. Zubar da ciki
Taro na bututun X-ray da bututun ya ƙunshi abubuwa kamar mai da ƙarfe masu nauyi waɗanda dole ne a tabbatar da amincin muhalli da zubar da su daidai da ƙa'idodin doka na ƙasa. ilimin fasaha da ake buƙata kuma zai ɗauki taron bututun X-ray baya don zubarwa.
Da fatan za a tuntuɓi sabis na abokin ciniki don wannan dalili.
Idan (A) Karamin Focal Spot
Idan (A) Babban Tabo Mai Kyau
Yanayi: Tube Voltage Mataki-Uku
Matsakaicin Wutar Lantarki 50Hz/60Hz
Saukewa: IEC60613
Halayen Thermal Gidaje
SRMWHX7010A
SRMWHX7010B
Tace Majalisar Da Ketare Na Port
Rotor Connector Wiring
Mafi ƙarancin oda: 1pc
Farashin: Tattaunawa
Marufi Details: 100pcs da kartani ko musamman bisa ga yawa
Lokacin Bayarwa: 1 ~ 2 makonni bisa ga adadi
Sharuɗɗan Biyan kuɗi: 100% T/T a gaba ko WESTERN UNION
Ikon iyawa: 1000pcs / watan